3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)
Page 37
If Error = 1, the device will not build MS2.0 format track data (if MS2.0 is enabled) if the indicated
track contains error(s).
If Blank = 0, the device will build MS2.0 format track data (if MS2.0 is enabled) if at least one track
contains good data – the indicated track may be blank.
If Blank = 1, the device will not build MS2.0 format Track data (if MS2.0 is enabled) if the indicated
track is blank.
3.4.10 Report 0x09 – Get Device Configuration
This command, when invoked in Get mode, will cause the device to send the current device configuration
to the host in the following report format:
Table 3-10 - Usage Table for Report 0x09 (Get mode)
Device Control (default value = 0x00)
Allow Charging in iAP mode
0x00 = disabled, default
0x01 = enabled
Mask Configuration (default value = 0xC0, all enabled except MS2.0)
00 = MS2.0 disabled
10 = MS2.0 enabled
MSR Card Configuration (default value = 0xD5, all enabled)
00=disabled
01=enabled
11=required
Leading length to leave unmasked
In SRED, maximum length = 6
In MS2.0 format, if >8, set to 8; if <5, set to 5
Trailing length to leave unmasked
In SRED, maximum length = 4
Ignored in MS2.0 format